CAD-SaftyNet BU Installation (CIT1)
- Scope
New Flow :
For any update or new cad interaction – the message is PUSHED to a predefined address and port.
- CIT Configuration
Open CIT and add:
- “CAD BU”
- Data Service for CAD is “DS_Generic”
- Go to Modules 🡪 Unit Types Toggling 🡪 Enable CAD
- Go to Modules 🡪 Generic Detection 🡪 Enable CAD
- Enable CAD Rule in RBE BU (sync + restart BU)
- Add CAD Organization Rule in RBE BU (sync + restart BU)
Define a new CAD Server Unit –
Cad Server is required per connection with CAD system.
Currently – the only required fields are Name and Port – since we are only “Listening” and not calling anywhere
This configuration will open a listening address of - AGS-APP2:8787
Testing
Using any rest client with address of the configuration above – AGS-APP2:8787/cadlistener ( postfix of the URL is required )
Result in CAD log:
2020-11-06 09:51:40.1118 [ 89] CadConnectorManager Warn Unexpected method ! ingnoring request
Sending a “call” – AKA CAD Detection
Sending a “unit” – AKA Dispatched Unit Detection
Further sample payloads will be provided